Installation / Details

On this page you will find detailed instructions on how to install Bumperite Waterguards on various surfaces. Please note that, to ensure safety, you must use components manufactured by Bumperite Waterguards, LLC and follow directions of a competent scaffold erector or structural engineer.

Steel Bent Plate | Wood Framing | Light Gauge Metal Framing | Quick-Tab Attachment | Concrete Recommended Seal Method | General Step-by-Step Details | Recommended Installation Sequence

Install Bumperite Waterguards with Welded Steel Anchor

Bumperite Waterguards may be installed to a steel bent plate using a welded steel anchor. Here’s how:

1. Determine spacing requirement to ensure safe scaffold erection.*
2. Measure distance between slab edge bent plate and outer face of stud framing.
3. Cut the anchor strut to length as to flush out with face of stud framing.
4. Align the anchor strut with the bent plate and stud framing (true, square, and plumb) per detail.
5. Weld anchor strut to building bent plate per welding detail shown.
6. The use of a certified welder and E7018 rod or equivalent is recommended.

*Spacing requirements for application should be determined by a competent scaffold erector or structural engineer per building and safety codes prior to installation. The temporary disconnection and reconnection of this product at erected scaffold should only be performed one connection at a time and only after it is determined safe to do so. The final determination of safety is the sole responsibility of the end user and should be determined by a competent and qualified person. Follow all OSHA, Federal, State, and Local requirements to ensure scaffold safety.

To ensure safety, use only components manufactured by Bumperite Waterguards, LLC at scaffold attachment.

Return to top.

Install Bumperite Waterguards to Wood Framing

Bumperite Waterguards may be installed to wood framing. Follow these instructions:

1. Determine spacing requirement to ensure safe scaffold erection.*
2. Review screw matrix provided to determine screw size and quantity required for safe installation.
3. Install BUMPERITE anchor plate where suitable framing and/or backing occurs to ensure sufficient strength required to carry intended scaffold load.
4. Apply compatible sealant between BUMPERITE anchor plate and building papers to ensure seal at screws.
5. Ensure complete screw embedment at pre-drilled holes in anchor plate.

*Spacing requirements for application should be determined by a competent scaffold erector or structural engineer per building and safety codes prior to installation. The temporary disconnection and reconnection of this product at erected scaffold should only be performed one connection at a time and only after it is determined safe to do so. The final determination of safety is the sole responsibility of the end user and should be determined by a competent and qualified person. Follow all OSHA, Federal, State, and Local requirements to ensure scaffold safety.

To ensure safety, use only components manufactured by Bumperite Waterguards, LLC at scaffold attachment.

Return to top.

Install Bumperite Waterguards to Light Gauge Framing

ALLOWABLE FORCE (P) = 500 LBS.

Minimum Design Requirements:

  • For scaffold application this product complies w/ OSHA requirements
  • 12 ga. Deck Edge Clip
  • 18 ga. Wall Studs 16″ O.C.
  • 6″x16 ga. x 1 1/2″ Flange Track
  • Track Blocking must be located within 6″ of Deck Edge Clip

Illustrations and load capacity provided FICCADENTI & WAGGONER, Consulting Structural Engineers, Inc.

Here is the procedure for installing Bumperite Waterguards to light gauge framing:

1. Determine spacing requirement to ensure safe scaffold erection.*
2. Review backing plate requirements.
3. Install BUMPERITE anchor plate over 12 gage backing plate per diagram to ensure sufficient strength required to carry intended scaffold load.
4. Apply compatible sealant between BUMPERITE anchor plate and building papers to ensure seal at screws.
5. Ensure complete screw embedment at pre-drilled holes in anchor plate.

*Spacing requirements for application should be determined by a competent scaffold erector or structural engineer per building and safety codes prior to installation. The temporary disconnection and reconnection of this product at erected scaffold should only be performed one connection at a time and only after it is determined safe to do so. The final determination of safety is the sole responsibility of the end user and should be determined by a competent and qualified person. Follow all OSHA, Federal, State, and Local requirements to ensure scaffold safety.

To ensure safety, use only components manufactured by Bumperite Waterguards, LLC at scaffold attachment.

Install Bumperite Waterguards Using Quick-Tab Attachment

An optional way to install BUMPERITE is to use the Quick-Tab Attachment:

  • The specially designed Quick-Tab is a scaffold erector’s dream.
  • Fast and easy installation with no hassle.
  • The Quick-Tab is a temporary attachment to the building slab edge during scaffold erection prior to exterior wall framing and final welded attachment of BUMPERITE WATERGUARD.
  • Available upon request. Contact the BUMPERITE sales office now for more details about the Quick-Tab Attachment.
  • See engineered detail.
  • WARNING: The Quick-Tab attachment is not to be used at tarped or enclosed scaffolds.

*Spacing requirements for application should be determined by a competent scaffold erector or structural engineer per building and safety codes prior to installation. The temporary disconnection and reconnection of this product at erected scaffold should only be performed one connection at a time and only after it is determined safe to do so. The final determination of safety is the sole responsibility of the end user and should be determined by a competent and qualified person. Follow all OSHA, Federal, State, and Local requirements to ensure scaffold safety.

To ensure safety, use only components manufactured by Bumperite Waterguards, LLC at scaffold attachment.

Return to top.

Install Bumperite Waterguards to Concrete

This is how you install BUMPERITE to concrete:

1. Determine BUMPERITE spacing requirement and concrete psi values suitable for safe scaffold erection.
2. Install BUMPERITE anchor plate at concrete slab edge with a minimum of two concrete anchor bolts, see engineered detail.
3. Install concrete anchors per manufacturer’s installation guidelines.
4. Ensure complete anchor bolt embedment for maximum strength.
5. See engineered detail.

*Spacing requirements for application should be determined by a competent scaffold erector or structural engineer per building and safety codes prior to installation. The temporary disconnection and reconnection of this product at erected scaffold should only be performed one connection at a time and only after it is determined safe to do so. The final determination of safety is the sole responsibility of the end user and should be determined by a competent and qualified person. Follow all OSHA, Federal, State, and Local requirements to ensure scaffold safety.

To ensure safety, use only components manufactured by Bumperite Waterguards, LLC at scaffold attachment.

Return to top.

The manufacturer recommends the use of Densglass Gold exterior sheathing, butyl sealant, Tyvek Straight Flash, minimum UU-B-790a grade D building paper, and three-coat cement plaster per testing report L-06-3059 from Smith-Emery Laboratories, Inc, using test method ASTM E331-00.

WARRANTY: Bumperite Waterguards, LLC’s liability expressed or implied is limited to the selling price of any defective goods. User shall determine the suitability of this produce for the intended use by doing field test before using, and assumes all risk and liabilities in connection therewith.

Return to top.

General Step-By-Step Bumperite Seal Installation at Welded Steel Anchor

Recommended Method of Seal at Wood / Steel Framed Anchor Plate to Exterior Water Management System

Water tested to ASTM E 1105-00 & ASTM E 331-00 by Architectural Testing, Inc.

Report No. 90353.01-701-43

WARRANTY: Bumperite Waterguards LLC Liability expressed or implied is limited to the selling price of any defected goods. User shall determine the suitability of this product for the intended use by performing field test before using, and assumes all risk and liabilities in connection therewith.

Return to top.